Service Hotline:
400 8483 886| Basic parameters | |
| Product branding | Galainer |
| Product model | GNC400HSF |
| Internal volume | 400L |
| Studio size | 800(W)*600(D)*850(H)mm |
| External dimensions | 1450(W)*1250(D)*1750(H)mm |
| Temperature control range | 0℃~ +150℃ -40℃~ +150℃ -60℃~ +150℃ (Optional) |
| Temperature fluctuations | ≤±0.5℃ |
| Temperature uniformity | ≤±1.0℃ |
| Temperature rise and fall rate | From +20~-40°C, about 40min From +20-100°C, about 30min |
| Humidity control range | 20%-98%RH(AT+20℃~+90℃) |
| wind velocity | 1.7 ~ 2.5m/s |
| Humidity error | ±2%RH |
| Supply voltage | 380V-50HZ |
| Product power | 5.5KW |
| Cargo carriers | 2 piece |
| Cabinet structure | |
Structure: The integral structure, that is, the test chamber, the refrigeration system, the heating/humidification system, the air conditioning system, the electrical control cabinet, and the refrigeration unit are a whole, the refrigeration unit is located at the bottom of the box, and the electrical control part is placed on the side of the test chamber for easy operation | |
Box: a) In the air duct mezzanine at one end of the studio, heat/humidifier, refrigeration evaporator, blower motor, fan blade and other devices are distributed; b) There is 1 cable threading hole on the side of the test chamber, and the size is ф50mm; c) The test chamber studio is made of 1mm thick SUS304 stainless steel plate, and the box shell is made of 1mm thick high-quality stainless steel d) The insulation material is made of polyurethane foam, with a thickness of 100mm, the insulation effect is good, and the outer surface of the test chamber does not frost or condensation. e) The studio is equipped with 1 layer of height-adjustable stainless steel shelves; f) The box is equipped with a condensate drain | |
Observation & Lighting Fixtures: A multi-layer insulating glass observation window is installed on the door, with a size of about 300×275mm, and is equipped with a heating and anti-frost device. A (AC12V) 20W halogen lamp is installed on the door of the test chamber. |
| Refrigeration system | |
| Compressor: The core of the refrigeration system is the compressor, we use "Taikang" and "Hitachi" fully enclosed compressor units (random) to form a set of refrigeration system to ensure the cooling requirements of the studio. The refrigeration system consists of a high-pressure refrigeration cycle and a low-pressure cold cycle, and the connecting vessel is an evaporator, and the function of the evaporative condenser is to use the low-pressure circulation evaporator as a high-pressure circulation condenser. | |
| Condensing evaporator: using the world's most advanced Swedish "Alfa Laval" ALfaLaval company or Sweden swep company production brazing plate heat exchanger, this heat exchanger is composed of a number of corrosion-resistant stainless steel sheets pressed into herringbone corrugations, adjacent to a pair of stainless steel sheets corrugated in opposite directions, corrugated back lines intersect with each other to form a large number of contact solder joints, due to the complex contact cross network channel makes the fluid on both sides form turbulence, increase and improve the heat exchange intensity, At the same time, the strong turbulence and smooth stainless steel surface make the inner surface of the channel of the brazed plate heat exchange less susceptible to fouling, and the system resistance is reduced to a minimum. | |
| Refrigeration system cooling mode: air cooling; | |
| Refrigerant: R404a |
| Heating system |
| Continuous PID regulation, using SSR solid state relay as heating actuator, safe and reliable, with a separate over-temperature protection system. |
| Humidification/Dehumidification/Waterway Systems: |
| Humidification method: stainless steel heating pipe, external humidification; |
| Dehumidification method: freezing dehumidification; |
| Waterway system: The water supply system of the equipment adopts a built-in stainless steel circulating water tank of about 20L, with low water consumption and stable circulation, the box is equipped with a drawer-type water box, and the liquid level display device of the circulating water tank is used to observe the water level, and the water shortage indicator is accompanied by an audible and visual alarm to remind the user to replenish the equipment water in time. The humidification system pipeline is separated from the power supply, controller, and circuit board, which can avoid affecting the circuit due to water leakage and improve safety. |
Air duct system |
| In order to ensure a high uniformity index, the test chamber is equipped with an internal circulating air supply system; In the air duct mezzanine at one end of the studio, heaters, refrigeration evaporators, fan blades and other devices are distributed; When the fan rotates at high speed, the air in the studio is sucked into the air duct from the bottom, and then blown out from the top of the air duct after heating and refrigeration, and the air after heat exchange with the sample in the studio is sucked into the air duct and circulated repeatedly, so as to meet the temperature setting requirements. |
| Control system |
The control system consists of: 1. Temperature measurement: Pt100 platinum resistance; 2. Humidity measurement: Pt100 platinum resistance wet and dry bulb method; 3. Control device: programmable temperature and humidity controller VISO6071/TEMI880 random. It can display the working status of set parameters, time, heater, humidifier, etc., and has the functions of automatic operation of test and self-tuning of PID parameters. 4. The automatic operation function of the refrigerator can be realized only by setting the temperature. The control system uses an intelligent control software system, which has the working conditions of automatic combination of refrigeration, heating, humidification and other subsystems, so as to ensure high-precision control in the entire temperature and humidity range and achieve the purpose of energy saving and consumption reduction. The perfect detection device can automatically carry out detailed fault display and alarm, such as when the test chamber is abnormal, the controller automatically displays the fault status. 5. Screen display: set temperature and humidity; measured temperature and humidity; Heating, humidification, time, temperature and humidity curves and other working statuses and various alarm indications. 6. Setting accuracy: temperature: 0.1°C humidity: 0.1%R.H 7. Program capacity: 100, the total number of program sections is 1000, and the maximum time of a single step of the program: 99 hours and 59 minutes; Programs can be looped, and programs can be linked to each other; 8. Operation mode: constant operation, program operation; 9. Other major low-voltage electrical components are made of well-known brand products: such as Schneider AC contactors, thermal overload relays, OMRON small intermediate relays, Delixi circuit breakers, Taiwan Fanyi water level float switches, etc. |
| Safety protection device |
1. Over-temperature protection of the studio; 2. Heater short-circuit protection; 3. Humidifier short-circuit protection; 4. Fan overload protection; 5. Compressor overpressure protection; 6. Compressor overload protection; 7. Water cut-off/water shortage protection; 8. Leakage protection; 9. Safe and reliable grounding device; |

Service Hotline
400 8483 886
Copyright © 2020-2024 Galainer Precision Humidity Control Equipment (Suzhou) Co., Ltd All rights reserved. | 苏ICP备16014397号-1